PM5358 S/UNI-4x622 Driver Manual
Data Structures
Proprietary and Confidential to PMC-Sierra, Inc. 40
Document ID: PMC-2010419, Issue 1
Field Name Field Type Field Description
ptimeprdi UINT1 Controls whether path trace identifier mismatch can cause
EPRDI insertion
paisconpais UINT1 Controls whether AIS concatenation events can cause PAIS
insertion
lopconpais UINT1 Controls whether loss of pointer concatenation events can
cause PAIS insertion
pslmpais UINT1 Controls whether path signal label mismatch can cause
PAIS insertion
pslupais UINT1 Controls whether path signal label unstable can cause PAIS
insertion
loppais UINT1 Controls wh eth er loss of sign al can caus e PAIS inserti on
tiupais UINT1 Controls whether path TIU can cause PAIS insertion
timpais UINT1 Controls whether path TIM can cause PAIS insertion
autopfebe UINT1 Controls whether path BIP errors can cause FEBE insertion
Per -Chan nel Paylo ad Processo r Configuration
Table 16: S/UNI-4x622 Payload Processor: sSUNI4x622_CFG_PYLD
Field Name Field Type Field Description
rxddscr UINT1 RX descrambles payload
rxcpdiscor UINT1 Disables ATM HCS error correction
rxcpidlepass UINT1 RX ignore idle cell header pattern and mask for ATM cells
rxcpccdis UINT1 Disables cell delineation and filtering
rxcplcdc UINT2 RX LCD Count Threshold
rxcpidlehdr UINT1 RX idle cell header
rxcpidlemask UINT1 RX idle cell mask
rxfpfcssel UINT1 RX FCS select
rxfpfcspass UINT1 RX selects FCS stripping