PMC-Sierra PM5358 S/UNI 4x622 manual Per-Channel Fifo Configuration

Models: PM5358 S/UNI 4x622

1 136
Download 136 pages 8.16 Kb
Page 41
Image 41

 

 

 

PM5358 S/UNI-4x622 Driver Manual

 

 

 

Data Structures

 

 

 

 

 

 

 

 

 

Field Name

Field Type

Field Description

 

 

 

 

 

rxfpminpl

UINT1

RX minimum packet length

 

 

 

 

 

rxfpmaxpl

UINT2

RX maximum packet length

 

 

 

 

 

txdscr

UINT1

TX scrambles outgoing payload

 

 

 

 

 

txcpidlehdr

UINT1

TX idle cell header

 

 

 

 

 

txcpidlepyld

UINT1

TX idle cell payload

 

 

 

 

 

txfpfcssel

UINT1

TX FCS select

 

 

 

 

 

mode

UINT1

ATM or POS mode

 

 

 

 

 

txfpipgap

UINT1

The number of Flag Sequence characters inserted between

 

 

 

each POS Frame

 

 

 

 

Per-Channel FIFO Configuration

Table 17: S/UNI-4x622 FIFO Configuration: sSUNI4x622_CFG_FIFO

Field Name

Field Type

Field Description

 

 

 

rxfpril

UINT1

RX FIFO overrun before frame receive

 

 

 

txfptil

UINT1

TX FIFO fill level before frame transmit

 

 

 

Per-Channel Clock Interface Configuration

Table 18: S/UNI-4x622 Clock Interface Configuration: sSUNI4x622_CFG_CLK

Field Name

Field Type

Field Description

 

 

 

loopt

UINT1

Selects REFCLK or recovered clock as tx source

 

 

 

dccsel

UINT1

Configures whether the DCC is configured for section or line

 

 

DCC operation

 

 

 

tfpen

UINT1

Controls whether frame pulse input used for alignment

 

 

 

Proprietary and Confidential to PMC-Sierra, Inc.

41

Document ID: PMC-2010419, Issue 1

 

Page 41
Image 41
PMC-Sierra PM5358 S/UNI 4x622 manual Per-Channel Fifo Configuration, Per-Channel Clock Interface Configuration