PM5358 S/UNI-4x622 Driver Manual

Data Structures

Line Overhead (LOH) Status

Table 27: S/UNI-4x622 Line Overhead Status: sSUNI4x622_STATUS_LOH

Field Name

Field Type

Field Description

 

 

 

k1

UINT1

Receive K1

 

 

 

k2

UINT1

Receive K2

 

 

 

s1

UINT1

Receive S1

 

 

 

laisdet

UINT1

Line alarm signal defect

 

 

 

lrdidet

UINT1

Line remote defect indication

 

 

 

sfber

UINT1

Signal Failure

 

 

 

sdber

UINT1

Signal Degrade

 

 

 

psbf

UINT1

APS byte failure

 

 

 

Receive Path Overhead (RPOH) Status

Table 28: S/UNI-4x622 Receive Path Overhead Processor Status: sSUNI4x622_STATUS_RPOH

Field Name

Field Type

Field Description

 

 

 

perdi

UINT1

Path enhanced RDI status(filtered received EPRDI bits,G1 bit

 

 

5,6 and 7)

 

 

 

rxptr

UINT2

Last payload pointer read from the receive stream

 

 

 

rxss

UINT1

Rx SS (DD) bits

 

 

 

txptr

UINT2

Current payload pointer being inserted in the tx stream

 

 

 

txss

UINT1

Tx SS bits

 

 

 

apsl

UINT1

Accepted path signal label

 

 

 

epsl

UINT1

Expected path signal label

 

 

 

plop

UINT1

Path lost of pointer status

 

 

 

pais

UINT1

Path AIS status

 

 

 