PM5358
Data Structures
Per-Channel RALRM Configuration
Table 19:
Field Name | Field Type | Field Description |
|
|
|
losen | UINT1 | Controls whether LOS set RALRM output |
|
|
|
lofen | UINT1 | Controls whether LOF set RALRM output |
|
|
|
oofen | UINT1 | Controls whether OOF set RALRM output |
|
|
|
laisen | UINT1 | Controls whether line AIS set RALRM output |
|
|
|
lrdien | UINT1 | Controls whether Line RDIset RALRM output |
|
|
|
sdberen | UINT1 | Controls whether SD threshold event set RALRM output |
|
|
|
sfberen | UINT1 | Controls whether SF threshold event set RALRM output |
|
|
|
stimen | UINT1 | Controls whether section TIM set RALRM output |
|
|
|
lopen | UINT1 | Controls whether LOP set RALRM output |
|
|
|
lcden | UINT1 | Controls whether LCD set RALRM output |
|
|
|
paisen | UINT1 | Controls whether path AIS set RALRM output |
|
|
|
prdien | UINT1 | Controls whether path RDI set RALRM output |
|
|
|
perdien | UINT1 | Controls whether path ERDI set RALRM output |
|
|
|
pslmen | UINT1 | Controls whether path signal label mismatch set RALRM |
|
| output |
|
|
|
ptimen | UINT1 | Controls whether path TIM set RALRM output |
|
|
|
conen | UINT1 | Controls whether pointer concatenation violation set RALRM |
|
| output |
|
|
|
Per-Channel Line Interface Configuration
Table 20:
Field Name | Field Type | Field Description |
|
|
|
cfgClk | sSUNI4x622_CFG_CLK | Clock configuration block |
|
|
|
Proprietary and Confidential to | 42 |