SpectraLink Corporation

Configuration and Administration—NetLink e340/i640 Wireless Telephone

 

 

 

Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation

 

 

 

 

 

 

 

Message

Description

Action

 

 

 

 

 

 

 

TFTP ERROR(x):yy

A failure has occurred during a TFTP software

Error code 01, 02, 07, or 16 - check the

 

 

 

download. (x) = The file number which was

TFTP server configuration.

 

 

 

being downloaded; yy is an error code

Error code 81, the handset will attempt to

 

 

 

describing the particular failure. Possible

 

 

 

download the file again.

 

 

 

error codes are:

 

 

 

For other messages, power off the handset,

 

 

 

01 = TFTP server did not find the requested

 

 

 

then turn it on again to retry the download.

 

 

 

file.

 

 

 

If the error repeats, note it and contact

 

 

 

 

 

 

 

02 = Access violation (reported from TFTP

SpectraLink Technical Support.

 

 

 

server).

 

 

 

 

07 = TFTP server reported "No such user"

 

 

 

 

error.

 

 

 

 

16 = No TFTP server address.

 

 

 

 

81 = File put into memory did not CRC.

 

 

 

 

FF = Timeout error. TFTP server did not

 

 

 

 

respond within a specified period of time.

 

 

 

 

 

 

 

 

Too Many Errors

The handset continues to reset and cannot

Fatal error. Return handset to SpectraLink.

 

 

 

be recovered.

 

 

 

 

 

 

 

 

Unknown

A phrase is missing from your phintl file.

Download new software from the

 

 

xx:yy:zz

 

SpectraLink site per Software

 

 

 

 

Maintenance.

 

 

 

 

 

 

 

Updating …

The handset is internally updating its

None. The handset may do this briefly after

 

 

 

software images

a download. This is informational only.

 

 

 

 

 

 

 

Updating Code…

Handset is downloading new software into

None. When the progress bar fills the

 

 

 

memory. The number icons at the bottom of

display line the update operation is

 

 

 

the display indicate which file number is

complete on that file.

 

 

 

currently being downloaded. This message

Do not turn the handset off during this

 

 

 

also displays a progress bar. When the

 

 

 

operation.

 

 

 

progress bar fills the display line the update

 

 

 

 

 

 

 

operation is complete on that file.

 

 

 

 

 

 

 

 

Waiting…

Handset has attempted some operation

None. The handset is waiting for a

 

 

 

several times and failed

specified period of time before attempting

 

 

 

 

that operation again.

 

 

 

 

 

 

 

Watchdog Timeout

The handset failed to hear from the

Verify the supported Mitel Networks VoIP

 

 

 

supported Mitel Networks VoIP solution

solution is operational and connected to

 

 

 

within the watchdog timeout interval.

the network.

 

 

 

 

 

 

 

Wrong Code Type

The software loaded into the handset is

Replace the software image on the TFTP

 

 

 

incorrect for this model phone

server with software that is correct for the

 

 

 

 

phone model.

 

 

 

 

 

 

PN: 72-1084-02-G.doc