SpectraLink Corporation

Configuration and Administration—NetLink e340/i640 Wireless Telephone

 

 

 

Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation

 

 

 

 

 

 

 

Message

Description

Action

 

 

 

 

 

 

 

Erasing Memory

Handset has determined that a download

None. When the progress bar fills the

 

 

 

should occur and is erasing the current

display line the erase operation is

 

 

 

software from memory.

complete.

 

 

 

 

Do not turn the handset off during this

 

 

 

 

operation.

 

 

 

 

 

 

 

Far End TCP Close

The handset has lost communication with the

No action necessary. After about 20

 

 

 

PBX.

seconds, the handset will re-initialize and

 

 

 

 

reconnect to either the same PBX or to

 

 

 

 

another PBX if it has been instructed to do

 

 

 

 

so or the first PBX fails to respond.

 

 

 

 

 

 

 

Files Too Big

Handset software download files are

Download new software from the

 

 

 

incorrect or corrupted

SpectraLink site per Software

 

 

 

 

Maintenance.

 

 

 

 

 

 

 

Flash Config Error

Handset internal configuration is corrupt.

Perform "Restore Defaults" operation via

 

 

 

 

administrator menus [or reprogram with

 

 

 

 

Configuration Cradle]

 

 

 

 

 

 

 

Forced Redirect

The PBX has told the handset to re-register

No action necessary.

 

 

 

with another PBX.

 

 

 

 

 

 

 

 

Get Button Defs

The Handset is attempting to get definitions

No action necessary.

 

 

 

from the PBX of how the user-programmable

 

 

 

 

keys are currently programmed.

 

 

 

 

 

 

 

 

Initializing …

The handset is performing power on

None. This is informational only.

 

 

 

initialization

 

 

 

 

 

 

 

 

Internal Err. # #

The handset has detected a fault from which

Record the error code so it can be

 

 

 

it cannot recover.

reported.

 

 

 

 

Turn the handset off then on again.

 

 

 

 

If error persists, try registering a different

 

 

 

 

handset to this telephone port.

 

 

 

 

If error still persists, contact SpectraLink

 

 

 

 

Technical Support and report the error.

 

 

 

 

 

 

 

Invalid Redirect

The PBX has told the handset to re-attempt

No action necessary.

 

 

 

registration with another PBX. The reason

 

 

 

 

code in the redirect message is invalid.

 

 

 

 

 

 

 

 

Multiple GW Res

More than one NetLink SVP Server has

Caused by two or more handsets sharing

 

 

 

responded

the same IP address. Assign unique IP

 

 

 

 

addresses to each phone.

 

 

 

 

 

 

 

Multiple SVP Reg

y…y = SVP IP address

This can happen if the handset has been

 

 

yyy.yyy.yyy.yyy

Handset received responses from multiple

re-configured to use a different SVP server

 

 

 

SVP Servers; displays IP address of one

and then powered-up before the previous

 

 

 

responding SVP Server

server has had time to determine that the

 

 

 

 

handset is no longer connected to it. The

 

 

 

 

problem should go away after about 30

 

 

 

 

seconds.

 

 

 

 

 

 

 

Must Upgrade SW!

Handset software is incompatible with

Download new software from the

 

 

 

hardware.

SpectraLink site per Software

 

 

 

 

Maintenance.

 

 

 

 

 

 

PN: 72-1084-02-G.doc

Page 55

Page 55
Image 55
Polycom SX-200 ICP, 72-1084-02, Mitel Networks 3300 manual Pbx