SpectraLink Corporation

Configuration and Administration—NetLink e340/i640 Wireless Telephone

 

 

 

Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation

 

 

 

 

 

 

 

Message

Description

Action

 

 

 

 

 

 

 

Bad Program File

Handset software download files are

Download new software from the

 

 

 

incorrect or corrupted

SpectraLink site per Software

 

 

 

 

Maintenance.

 

 

 

 

 

 

 

(battery icon),

Low battery

In call: the battery icon displays and a soft

 

 

Battery Low,

 

beep will be heard when the user is on the

 

 

beep (audio)

 

handset and the battery charge is low. User

 

 

 

 

has 15–30 minutes of battery life left.

 

 

 

 

The Battery Pack can be changed while the

 

 

 

 

call is still in progress. Do not press End

 

 

 

 

Call. Place call on Hold or Park. Quickly

 

 

 

 

remove the discharged battery and replace

 

 

 

 

with a charged battery, power on the

 

 

 

 

handset, and press Start Call to resume

 

 

 

 

the call in progress.

 

 

 

 

Not in call: The battery icon displays

 

 

 

 

whenever the battery charge is low The

 

 

 

 

message Battery Low and a beep indicate

 

 

 

 

a critically low battery charge when user is

 

 

 

 

not on the handset. The handset will not

 

 

 

 

work until the Battery Pack is charged.

 

 

 

 

 

 

 

Battery Failure

The Battery Pack is not functioning.

Replace the Battery Pack with a new or

 

 

 

 

confirmed SpectraLink Battery Pack. Any

 

 

 

 

non-Spectra-Link Battery Packs will not

 

 

 

 

work.

 

 

 

 

 

 

 

Battery Failed

Battery Pack is damaged or incompatible

Replace the Battery Pack with a new or

 

 

 

with handset.

confirmed SpectraLink Battery pack. Any

 

 

 

 

non-SpectraLink Battery Packs will not

 

 

 

 

work.

 

 

 

 

 

 

 

Can’t Renew DHCP

y…y = DHCP server IP address

Configuration problem. Check the IP

 

 

yyy.yyy.yyy.yyy

DHCP server is not responding to initial

address configuration in the DHCP server.

 

 

 

renewal attempt

 

 

 

 

 

 

 

 

Charging …

The handset is charging in the Desktop

No action needed.

 

 

 

Charger.

 

 

 

 

 

 

 

 

Charge Complete

The handset is now fully charged.

No action needed.

 

 

 

 

 

 

 

Checking Code

Handset is contacting the TFTP server to

None, this message should only last for

 

 

 

determine if it has a newer version of

approximately one second. If message

 

 

 

software that should be downloaded.

remains displayed, power off and contact

 

 

 

 

customer support for a replacement

 

 

 

 

phone.

 

 

 

 

 

 

 

Checking DHCP IP

The handset is retrieving DHCP information

None. This is informational only.

 

 

 

from the DHCP server

 

 

 

 

 

 

 

 

CRC Code Error

The software which has been TFTP

Try the download again; it is possible the

 

 

 

downloaded has a bad redundancy code

software was corrupted during download. If

 

 

 

check

the error repeats, check that the download

 

 

 

 

image on the TFTP server is not corrupted.

 

 

 

 

 

 

 

Code Mismatch!

The software loaded into the handset is

Verify the License Management value is

 

 

 

incorrect for this model handset

correct. Replace the software image on the

 

 

 

 

TFTP server with software that is correct for

 

 

 

 

the handset model.

 

 

 

 

 

 

PN: 72-1084-02-G.doc