Message

Description

Action

 

 

 

 

 

 

 

No PBX Response

The handset has exceeded its retransmission

Verify that Call Agent IP address and port

 

 

 

limit with no ACK response from Call Agent.

are properly configured.

 

 

 

 

 

 

 

No Reg Domain

Regulatory Domain Not Set

Configure the Regulatory Domain of the

 

 

 

 

handset

 

 

 

 

 

 

 

No SVP IP

The handset is configured for “static IP” (as

Enter a valid NetLink SVP server IP address

 

 

 

opposed to “use DHCP”) and no valid

in the configuration setting or change to

 

 

 

NetLink SVP Server address has been

“use DHCP.”

 

 

 

entered.

 

 

 

 

 

 

 

 

No SVP Response

y…y = SVP Server IP address

This may be caused by bad radio reception

 

 

yyy.yyy.yyy.yyy

Handset has lost contact with the SVP Server.

or a problem with the NetLink SVP Server.

 

 

 

 

The handset will keep trying to fix the

 

 

 

 

problem for 20 seconds, and the message

 

 

 

 

may clear by itself. If it does not, the

 

 

 

 

handset will restart. Report this problem to

 

 

 

 

the system administrator if it keeps

 

 

 

 

happening.

 

 

 

 

 

 

 

No SVP Server

Handset can’t locate NetLink SVP Server

IP address configuration of NetLink SVP

 

 

 

 

Server is wrong or missing.

 

 

 

NetLink SVP Server is not working

Check error status screen on NetLink SVP

 

 

 

 

Server.

 

 

 

No LAN connection at the NetLink SVP Server

Verify NetLink SVP Server connection to

 

 

 

 

LAN.

 

 

 

 

 

 

 

No SVP Server

Handset unable to perform DNS lookup for

The network administrator must verify that

 

 

No DNS Entry

SVP Server, server had no entry for SVP

a proper IP address has been entered for

 

 

 

Server

the SVP Server DHCP option.

 

 

 

 

 

 

 

No SVP Server

Handset unable to perform DNS lookup for

The network administrator must verify

 

 

No DNS IP

SVP Server, no IP address for DNS server

proper DHCP server operation.

 

 

 

 

 

 

 

No SW Found

A required software component has not been

Check that the handset license type has a

 

 

 

identified.

corresponding entry in the slnk_cfg.cfg

 

 

 

 

file.

 

 

 

 

Check that the pd11mgd.bin and

 

 

 

 

pi110000.bin entries exist in under this

 

 

 

 

license type in the slnk.cfg.cfg file.

 

 

 

 

 

 

 

Not Installed!

A required software component is missing

Check that all required software files are

 

 

 

 

on the TFTP server, if over-the-air

 

 

 

 

downloading is being used. If the error

 

 

 

 

repeats, contact SpectraLink Technical

 

 

 

 

Support.

 

 

 

 

 

 

 

Press END Call

The far end of a call has hung up.

Hang up the near end.

 

 

 

 

 

 

 

Register to PBX

The handset is attempting to register to the

If this message persists, verify that the

 

 

 

PBX.

handset is properly provisioned on the PBX

 

 

 

 

and that the 5220 Emulation mode is set

 

 

 

 

properly in the administrative menus.

 

 

 

 

 

 

 

Restart Command

The Handset received a restart command

None. The Handset will automatically

 

 

 

from the supported Mitel Networks VoIP

restart in a few seconds.

 

 

 

solution.

 

 

 

 

 

 

 