Safety Approval

When identified with the ETL-c logo, the treadmill has been tested and conforms to the requirements of CAN/CSA-E-335-1/2-94, Safety of Household and Similar Electrical Appliances.

Grounding Instructions

The M9.55 Low Impact Treadmill must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current which reduces the risk of electrical shock. The treadmill is equipped with a power cord having an equipment-grounding conductor and a grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accor- dance with all local codes and ordinances. If you do not follow these Grounding Instructions, you could void the Precor limited warranty.

Diagram 1

Correct power outlet for U.S. Markets: 15 amp

120-volt and 240-volt plugs.

120-volt grounding plug

240-volt grounding plug

DANGER

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the treadmill is properly grounded. Do not modify the plug provided with the treadmill—if it doesn’t fit the outlet, get a proper outlet installed by a qualified techni- cian.

120V Units Designated for U.S. Markets

The M9.55 treadmill must be connected to a 20 amp dedicated circuit having a nominal rating of 120-volts. The treadmill’s grounding plug looks like the plug illus- trated in Diagram 1. The power outlet must have the same configuration as the plug. No adapter should be used with this product.

240V Units Designated for U.S. Markets

The M9.55 treadmill must be connected to a 20 amp dedicated circuit having a nominal rating of 240-volts. The treadmill is factory-equipped with a specific power supply cord to permit connection to a proper electric circuit. Make sure that the treadmill is connected to an outlet having the same configurations as the plug. See Diagram 1. No adapter should be used with this product. If the treadmill must be reconnected for use on a different type of electrical circuit, the reconnection must be made by qualified service personnel.

ATTENTION: Haute Tension

Débranchez avant de réparer

page 5