2700-I ACC Wood Insert

Prefabricated Metal Chimney (Cont’d)

 

Inches

Millimeters

Minimum Width of Cavity Opening - Front

32-1/2

775

Minimum Width of Cavity Opening - Rear

20

508

Minimum Height

18-11/16

475

Minimum Depth from Front to Rear

17-1/4

438

NOTE: Refer to chimney liner manufacturer for recom- mendations on supporting the liner. Installation into fireplaces without a permit will void the listing.

NOTICE: In Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

WARNING

Fire Risk.

When lining air-cooled factory-built chimneys:.

Run chimney liner approved to UL 1777 Type HT requirements (2100 degrees F)

Re-install original factory built chimney cap

ONLY

DO NOT block cooling air openings in chimney

Blocking cooling air will overheat the chimney

G. Securing Chimney Components

All joints should be secured with 3 sheet metal screws or rivets per pipe manufacturers instructions. The sections must be attached to the insert and to each other with the crimped (male) end pointing toward the insert. Figure 37.1.

LINER CONNECTOR

CRIMPED

FLUE

END

GAS

TOWARDS

DIRECTION

STOVE

 

Figure 37.1

H. Altering the Fireplace

The following modifications of factory-built fireplaces are permissible:

The following parts may be removed:

Damper

Smoke Shelf or Baffle

Ember Catches

Fire Grate

Viewing Screen/Curtain

Doors

The fireplace must not be altered, except that the damper may be removed to accommodate a direct-connect starter pipe or chimney liner,

External trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed.

To maintain the functionality of the fireplace’s chimney system you may use a Simpson Dura-Vent DuraLiner Slip Hanger, Part # 4671, and attach to the bottom of the fireplace chimney cap to support the liner. You have two options to completing the installation.

Option one - Not required to use liner cap: Re-attach the existing top of the chimney cap.

Option two - Using liner cap:

Re-attach the existing top of the chimney cap and install a new storm collar and a new liner cap.

The permanent metal warning label provided in the component pack must be attached to the back of the fireplace, with screws or nails, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fireplace. Figure 37.2.

If the hearth extension is lower than the fireplace opening, the portion of the insert extending onto the hearth must be supported.

Manufacturer designed adjustable support kit can be ordered from your dealer.

Final approval of this installation type is contingent upon the authority having jurisdiction.

WARNING! Risk of Fire!

Follow venting manufacturer’s clearances and instructions when installing venting system.

WARNING

THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT. IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE.