R

2700-I ACC Wood Insert

 

 

5 Service Parts Replacement

 

A. Glass Replacement

B. Snap Disc Replacement

 

(Replace with 5mm ceramic glass only)

1. Locate the snap disc bracket assembly in the blower

1.

Ensure that the fire is out and the appliance is cool to

housing under the ash lip. Figure 21.1

 

the touch.

2. Using a 5/32 Allen wrench, remove the 4 mounting bolts

2.

Protect a table or counter top with padding or towels.

and slide assembly towards you.

 

Protect your hands and wear gloves to prevent injury.

3. Using a Phillips head screw driver, remove the 2 screws

3.

Remove the door with the broken glass by lifting the

from the snap disc and lift the snap disc off of the mounting

 

door up and off of the hinges.

bracket. Disconect the wires and replace with new snap

4.

Lay door face down on a table or counter making sure

disc and re-connect the wires. Figure 21.2.

 

the handle hangs over the edge so the door lays flat, on

4. Slide the blower housing back into position and secure with

 

a soft surface.

the 4 mounting bolts.

5.

Remove the screws from each glass retainer and remove

 

 

the glass. (If screws are difficult to remove, soak with

 

 

penetrating oil first).

 

6.

Center the glass with edges evenly overlapping the

 

 

opening in the door, (i.e. same space top and bottom,

 

 

left and right sides).

 

7.

Replace the glass retainers. Be careful not to cross

Snap Disc Location

 

thread the screws.

 

8.

Tighten each retainer just a few turns until each is

 

 

secured. Check again for centering of glass in door

 

 

frame. Continue to tighten each retainer alternately, a

 

 

few turns at a time, until the glass is secure. DO NOT

 

 

OVERTIGHTEN - can cause glass to break.

 

9.

Replace the door on the appliance.

 

WARNING! Risk of Fire or Injury!

Remove Bolts and Slide

Use only glass that is specified in the manual, DO NOT

Blower Assembly Out

replace with any other material. Glass breakage will occur.

 

CAUTION!

Handle glass with care.

Inspect the gasket to ensure it is undamaged.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass & door assembly removed.

Do NOT operate with glass cracked, broken or scratched.

Quadra-Fire appliances are equipped with ceramic super heat-resistant glass, which can only be broken by impact or misuse.

Figure 21.1 Snap Disc Location

Snap Disc

Figure 21.2