D. Locating Your Stove & Chimney

Location of the appliance and chimney will affect perfor- mance. As shown in Figure 27.1 the chimney should:

Install through the warm space enclosed by the build- ing envelope. This helps to produce more draft, espe- cially during lighting and die down of the fire.

Penetrate the highest part of the roof. This minimizes the affects of wind turbulence and down drafts.

Consider the appliance location in order to avoid floor and ceiling attic joists and rafters.

Locate termination cap away from trees, adjacent structures, uneven roof lines and other obstruc- tions.

Your local dealer is the expert in your geographic area and can usually make suggestions or discover solutions that will easily correct your flue problem.

Recommended Recommended

Location Location

Marginal

Location

Location

Not

Recommended

Location NOT

Recommended

Windward

Outside Termination Cap

Leeward

Multi-level Roofs

Figure 27.1

E. Chimney Termination Requirements

Follow manufacturer’s instructions for clearance, securing flashing and terminating the chimney.

Must have an approved and Listed cap

Must not be located where it will become plugged by snow or other material

Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm).

Must be located away from trees or other structures

Notice: Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near

Frequently open doors

Central heat outlets or returns

NOTICE:

Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.