R

2700-I ACC Wood Insert

H. Blower Cord Installation on Left Side

The blower cord is shipped to be installed on the right side of the appliance. You may relocate the cord so it is on the left side. You remove the blower control plate and wire har- ness as one assembly and reconnect on the left side. The cover plate on the left side is re-attached on the right side.

Instructions

1.Remove the blower assembly from the appliance. Using a 5/32 Allen wrench remove the 4 mounting bolts and slide the assembly towards you.

2.Using needle nose pliers bend the tabs up that holds the wire harness in place and remove the wires. There are 2 tabs, one at the top of the assembly and one at the bottom.

3.Disconnect the power leads to the blower.

4.Remove the snap disc mounting plate by removing the 2 sheet metal screws with a Phillips head screw driver.

5.Disconnect the spade terminals to the snap disc.

6.Remove the blower control plate using a flat head screw driver to remove the 2 screws, 1 on the top and 1 on the bottom. Remove the blower control plate and wire har- ness at the same time.

7.On the left end of the blower housing, remove the cover plate and re-install on the right end of the housing.

8.Install the blower control plate on the left end and secure the wire harness underneath the tabs on the left side and bend the tabs back into position.

9.Re-connect the spade terminals to the snap disc and re- install the snap disc assembly.

10.Re-connect the power leads to the blower.

Snap Disc Location

Remove Bolts and Slide

Blower Assembly Out

Figure 43.1

 

 

 

 

 

 

 

 

 

 

Snap Disc

 

 

 

Blower

 

 

 

Mounting Plate

 

 

 

 

 

Control

Cover

 

 

 

 

 

 

 

 

 

 

Plate

Plate

 

 

 

 

 

 

Snap Disc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Harness Tabs Locations

Left Side

Right Side

 

Figure 43.2

Bend Wire Harness Tab

Figure 43.3

Snap Disc

Mounting Plate

Disconnect Spade

Terminals from Snap Disc

Figure 43.4

Figure 43.5 - Installed on Left Side

December 15, 2009

7046-137C

Page 43

Page 43
Image 43