2700-I ACC Wood Insert

F. 2-10-3 Rule

These are safety requirements and are not meant to assure proper flue draft.

This appliance is made with a 6 inch (152mm) diameter chimney connector as the flue collar on the unit.

Changing the diameter of the chimney can affect draft and cause poor performance.

It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other factors that affect flue draft.

R

ft. (91cm) Minimum

2 ft. (61cm)

10 ft. (05cm) To Nearest Roofline

Less than 10 ft. (05cm)

2 ft. (61cm)

ft. (91cm) Minimum

Figure 28.1

Pitched Roof

10 ft. (305cm) or more

Less than 10 ft. (305cm)

 

 

Wall or Parapet

2 ft. (61cm)Minimum

3 ft. (91cm) Minimum

3 ft. (91cm) Minimum

 

Figure 28.2

Flat Roof

 

Page 28

7046-137C

December 15, 2009

Page 28
Image 28
Quadra-Fire 7046-137C warranty ACC Wood Insert Rule, Flat Roof