RS-422 Connections

In the RS-422 mode, TXD lines are outputs and RXD lines are inputs. Connect the TXDB(+) line to the RXDB(+) line of your device, and the TXDA(-) line to the RXDA(-) line of your device.

If Flow Control is set for RTS/CTS, connect the RTSB(+) line to the CTSB(+) line of your device and RTSA(-) to CTSA(-) of your device. Connect from CTSB(+) to RTSB(+) of your device and from CTSA(-) to RTSB(+) of your device.

If connecting to Receive Only RS-422 devices, connect from TXDB(+) and TXDA(-) to the receive pairs on all your devices.

Ground is signal ground and provides a common mode reference for the RS-422 Receiver and Transmitters.

The RS-422 mode can be used for full duplex 4-wire RS-485 operation provided that the DSE-410D is acting as a sole master connecting to all the slave devices, and all slave devices share the Receive signal lines to the master. Set Flow Control for none, and omit connections to RTS/CTS line pairs.

12

DSE-410D Owner’s Manual – Document Number: 940-0186-100

Quatech, Inc. - 5675 Hudson Industrial Parkway, Hudson, OH 44236 – 330.655.9000

http://www.quatech.com

Page 18
Image 18
Quatech DSE-410D manual RS-422 Connections