Chapter 2

Installation and Setup

This chapter provides the following information for the ASMi-31 standalone model:

Site requirements and prerequisites

Package contents

Instructions for mechanical installation

Instructions for electrical installation.

After installing the unit, refer to Chapter 3 to assure normal operation.

In case a problem encountered, refer to Chapter 4 for test and diagnostic instructions.

Refer to Chapter 5 for additional information on the ASMi-31/R card version.

 

2.1 Site Requirements and Prerequisites

Power

AC-powered ASMi-31 units should be installed within 1.5m (5 ft) of an

 

easily accessible grounded AC outlet. The outlet should furnish 115 VAC or

 

230 VAC.

DC-powered ASMi-31 units require -48 VDC power source, which must be adequately isolated from the mains supply.

Allow at least 90 cm (36 in) of clearance at the front for operating and maintenance accessibility.

Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables.

Ambient

The ambient operating temperature of ASMi-31 is 0 to 50°C (32 to 122°F)

Requirements

at relative humidity of 90%, non-condensing.