ASMi-31Installation and Operation Manual

Chapter 2. Installation and Setup

 

 

To connect the line:

1. Insert the screwdriver into a square hole (see Figure 2-3).

Figure 2-3 Connecting the Line – Step 1

2.Raise the inserted screwdriver, putting pressure on the ramp within the square hole (see Figure 2-4).

Figure 2-4 Connecting the Line – Step 2

3.Insert the stripped end of the wire and remove the screwdriver (see Figure 2-5).

Figure 2-5 Connecting the Line – Step 3

Connecting the DTE

The rear-panel DTE connector provides interface for data input/output, clock reference and control signal exchange between ASMi-31 and the DTE. The DTE interface is changeable module with the interface connector. The DTE is connected to ASMi-31 via adapter cables depending on the interface type, see Table 2-2to select the correct cable for your DTE interface.

Table 2-2 DTE Interfaces and Matching Adapter Cables

DTE Interface

Connector Description

RAD Cable

 

 

 

V.24/RS-232

25-pin, D-type, female

CBL-HBT/V24

 

 

 

V.35

34-pin, female

CBL-HBT/V35

 

 

 

X.21

15-pin, female

CBL-HBT/X21

 

 

 

Installation and Setup

2-7

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 27
Image 27
RAD Data comm ASMi-31 operation manual To connect the line, Connecting the DTE, DTE Interfaces and Matching Adapter Cables