Appendix E Connecting RS-530 to RS-422

ASMi-31Installation and Operation Manual

 

 

 

 

 

 

 

 

 

 

 

Table E-1

Connecting RS-530 to RS-422 (Cont.)

 

 

 

 

 

 

 

 

 

 

 

Signal Function

RS-449 (RS-422/423)

 

RS-530

 

 

 

 

 

 

 

 

 

 

 

 

37-pin

 

 

DB-25 Female

 

 

 

 

 

 

 

 

Standalone & Card

 

 

 

 

Pin

 

Circuit

Cage

 

Circuit

 

 

 

 

 

 

Pin

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit Clock

5

 

ST (A)

15

 

DB (A)

 

(From DCE)

23

 

ST (B)

12

 

DB (B)

 

 

 

 

 

 

 

 

 

Receive Clock

8

 

RT (A)

17

 

DD (A)

 

(From DCE)

26

 

RT (B)

9

 

DD (B)

 

 

Local Analog Loopback

10

 

LL

18

 

LL

 

 

Remote Loopback

14

 

RL

21

 

RL

 

 

Test Indicator

18

 

TM

25

 

TM

 

 

 

 

 

 

 

 

 