Appendix E

Connecting RS-530 to

RS-422

 

Table E-1

Connecting RS-530 to RS-422

 

 

 

 

 

 

 

Signal Function

RS-449 (RS-422/423)

RS-530

 

 

 

 

 

 

 

 

37-pin

 

DB-25 Female

 

 

 

 

 

Standalone & Card

 

 

 

Pin

Circuit

Cage Pin

 

Circuit

 

 

 

 

 

 

Protective Ground

1

Shield

1

 

 

Signal Ground

19

SG

7

 

AB

DTE Common Return

37

SC

 

 

 

DCE Common Return

20

RC

 

 

 

Transmitted Data

4

SD (A)

2

 

BA (A)

 

22

SD (B)

14

 

BA (B)

Received Data

6

RD (A)

3

 

BB (A)

 

24

RD(B)

16

 

BB (B)

Request to Send

7

RS (A)

4

 

CA (A)

 

25

RS (B)

19

 

CA (B)

Clear to Send

9

CS (A)

5

 

CB (A)

 

27

CS (B)

13

 

CB (B)

Data Set Ready

11

DM (A)

6

 

CC (A)

 

29

DM (B)

22

 

CC (B)

Carrier Detect

13

RR (A)

8

 

CF (A)

 

31

RR (B)

10

 

CF (B)

External Transmit

17

TT (A)

24

 

DA (A)

Clock

35

TT (B)

11

 

DA (B)

 

 

 

 

 

 

E-1

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 61
Image 61
RAD Data comm ASMi-31 operation manual Appendix E Connecting RS-530 to RS-422