Chapter 2. Installation and Setup

ASMi-31Installation and Operation Manual

 

 

 

 

 

 

 

 

 

 

 

 

2

CHASS-GND

CON

JP18

DIS

 

1

JP14 RLB

DIS

EN

EN

DIS

LLB

JP15

CLOCK

JP9

LBT

INT

 

EXT

3

4

SLAV DSR DCD 1STB

EVEN P.EN 8BIT

ASY

SW6

SW7

 

9

A

B

C

 

 

 

 

 

 

8

 

 

 

 

D

 

 

 

 

 

 

E

 

7

 

 

 

 

F

 

6

 

 

 

 

 

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP

 

7 8

MAST

 

DTR

 

 

6

CNT

 

 

5

2STB

 

 

ODD

 

 

4

 

 

DIS

 

 

 

 

 

 

 

 

2

7BIT

 

 

1

SYNC

 

 

 

 

 

 

 

POS BAUD

00.6K

11.2K

22.4K

34.8K

49.6K

519.2K

638.4K

748K

8*56K

964K A 128K B *144K C *57.6K D *115.2K E 16K

F 32K

5

 

 

 

6

 

 

 

* Baud rates not applicable.

 

 

 

 

Figure 2-1 ASMi-31 PCB Layout

 

 

 

Table 2-1 ASMi-31 Internal Jumpers and Switches

 

 

 

 

 

 

Item

Jumper

Description

Values

Default Setting

 

 

 

 

 

1

RLB, JP14

Controls the remote loopback

DIS – The RLB activation from

DIS

 

 

activation from the DTE

the DTE is disabled

 

 

 

 

EN – The RLB activation from

 

 

 

 

the DTE is enabled

 

2

CHASS-GND,

Controls the connection

CON – Signal ground is

CON

 

JP18

between the ASMi-31 signal

connected to the frame ground

 

 

ground and the frame (chassis)

DIS – Signal ground is

 

 

 

ground

disconnected from the frame

 

 

 

 

ground

 

Note: Disconnecting the signal ground from the frame ground may render the unit unsafe for connection to unprotected telecommunication networks in some locations.

2-4 Installation and Setup

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 24
Image 24
RAD Data comm ASMi-31 PCB Layout ASMi-31 Internal Jumpers and Switches, Jumper Description Values Default Setting