Chapter 2 Installation

MBE Family Installation and Operation Manual

 

 

 

 

 

Rate

POS

 

 

 

768

0

BOT

 

256

1

 

128

2

0

1

2

96

3

 

 

64

4

 

 

3

48

5

7 6 5

4

32

6

16

7

IL-4W

 

 

 

Rate

POS

 

 

 

 

 

 

768

0

 

 

 

BOT

 

256

1

TOP

 

 

128

2

 

0

1

2

96

3

0

1

2

 

 

64

4

 

 

 

 

3

48

5

 

 

3

7 6 5 4

32

6

7 6 5 4

16

7

 

 

 

IL-4WD

 

 

 

Note

Figure 2-2. 4W Date Rate Selection

BOT- corresponds to the lower link connector.

TOP - corresponds to the upper link connector.

Table 2-2. MBE Four-Wire Data Rate

Data Rate

Range

Selector Position

(kbps)

km/miles

 

 

 

 

768

1.0/0.6

0

 

 

 

256

3.0/1.8

1

 

 

 

128

4.5/2.7

2

 

 

 

96

5.5/3.3

3

 

 

 

64

6/3.7

4

 

 

 

48

7/4.3

5

 

 

 

32

6.5/4.0

6

 

 

 

16

6/3.7

7

 

 

 

2-6

Installation and Setup

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 32
Image 32
RAD Data comm MBE10-1D, MBE10-8D operation manual IL-4W