Regency L676-NG1 Installation, Vertical Venting with Three 3 90o Elbows, Vent Restrictor Setting

Models: L676-NG1 L676-1 L676-LP1

1 48
Download 48 pages 15.04 Kb
Page 21
Image 21
Vertical Venting with Three (3) 90o Elbows

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

INSTALLATION

Option

V H + H1 V + V1

A)2' Min. 2' Max. 4' Min.

B)3' Min. 4' Max. 6' Min.

C)4' Min. 5' Max. 7' Min.

D)5' Min. 6' Max. 8' Min.

E)6' Min. 8' Max. 9' Min.

With these options, max. total pipe length is 30 feet with min. of 9 feet total vertical and max. 8 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

INSTALLATION

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.