INSTALLATION

 

INSTALLATION

 

 

6) Remove the burner tube by removing the 2 10) Re-install the pilot cap.

13) Remove NG modulating regulator by

screws.

undoing 3 screws and replace with LP

11) Undo the center wire clip on the side of the

modulating regulator.

fi rebox.

 

INSTALLATION

Burner Tube

7)Remove the burner orifice with a 1/2" wrench. Use another wrench to hold onto the elbow behind the orifi ce. Replace the NG burner orifi ce with LP orifi ce #51.

Burner Orifi ce

8)Pull off the pilot cap to expose the pilot orifi ce.

9)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifi ce.

12)Unplug the wire harness that connects the modulating coil to the receiver.

14)Install the enclosed identifi cation label to the valve body where it can be easily seen.

15)Attach the LP conversion decal near or on top of the serial no. decal.

16)Replace yellow "Natural Gas" label with red "Propane" label.

17)Adjust the burner aeration setting to the LP setting (5/16") and re-install the burner tube.

18)Re-install the grate.

19)Re-install the burner orifi ce cover plate.

20)Re-install the glass door.

21)Re-install the front cover plate

22)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a)Turn on the gas supply and check for gas leaks.

b)Check the inlet and outlet pressures.

c)Check operation of fl ame control using the remote control.

d)Check for proper fl ame appearance.