VENT RESTRICTOR POSITION

INSTALLATION

VENT RESTRICTOR POSITION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.

The Vent Restrictor plate is located on the inside top of the firebox.

Vent Restrictor Plate

2)Remove the front cover plate by lifting up off of the pins on the left and right side of the firebox.

6)Once the vent restrictor plate is in the required position, secure with screws.

Screws for plugging the holes.

(all holes must be plugged with a screw).

Screw holes for fixing the restrictor plate.

INSTALLATION

To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;

1)Remove the right side mesh by gathering the mesh together and lifting the curved end of the rod up and out of the bracket located on the top right of the glass frame.

Now slide the straight end of the rod out from the bracket located on the middle inside top of the outer shell. Repeat for left side.

Front Cover Plate

Right Side Pin Shown

3) Remove the glass door.

a. Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

Latch

7) Vent Restrictor Set 4 = combination of Vent Restrictor Set 1 + installation of the baffle plate (see below).

b. Swing the door out from the top and release the hinge on the left side of the door and lift out.

 

Hinge
Door

4)

Remove the screws that hold the vent

 

restrictor plate in place.

 

5)

Adjust the vent restrictor plate to the required

Right Side Rod with Screen Removed

vent restrictor position as per the diagrams

shown.

 

Relief Doors

Baffle plate

 

Vent Restrictor Set 4

Note: Used only with specific limited horizontal termination. See chart on p. 19 in this manual for details.

Position the baffle plate on the top inside wall of the firebox, push it back until it contacts the back wall of the firebox. Center it between the 2 relief doors (see above diagram), secure with 2 self tapping screws provided.