Regency L676-LP1, L676-NG1 Installation, Horizontal Venting with Two 2 90o Elbows, Option, H + H1

Models: L676-NG1 L676-1 L676-LP1

1 48
Download 48 pages 15.04 Kb
Page 20
Image 20
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these

options,

A)

2'

Min.

4' Max.

maximum total pipe length

B)

3'

Min.

6' Max.

is 30 feet with minimum

C)

4'

Min.

8' Max.

of 6 feet total vertical and

 

 

 

 

maximum 10

feet total

D)

5'

Min.

9' Max.

 

 

 

 

horizontal.

 

E)

6' Min.

10' Max.

 

 

 

Please note minimum 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 3' Min. 2' Max.

B)2' Min. 2' Max. 5' Min. 4' Max.

C)3' Min. 2' Max. 7' Min. 5' Max.

D)4' Min. 3 Max. 9' Min. 6' Max.

E)5' Min. 4' Max. 10' Min. 7' Max.

F)6' Min. 6' Max. 11' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor factory set at Set 1, no adjustment required.