Regency L676-LP1 Installation, Heat Release Kit, Finished Floor, Locating Your Gas Fireplace

Models: L676-NG1 L676-1 L676-LP1

1 48
Download 48 pages 15.04 Kb
Page 8
Image 8
This includes:

INSTALLATION

INSTALLATION

9)Test Gas Pressure (Refer to "Gas Pipe Pres- sure Testing" section).

10)Install standard and optional features. Refer to the following sections:

a)Brick Panels

b)Log Set

c)Remote Control - refer to "Matching Remote Handset & Control Box ID Code" section.

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

3)The L676-1 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See

Diagram 1.

A)Flat on Wall

B)Flat on Wall Corner

C) Recessed into

Wall/Alcove

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the fireplace to the outside of the building, allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side.

See Heat Release installation manual for complete details and clearances from side only.

FINISHED FLOOR

The maximum height that combustible floor can be brought above the base of the unit is 3".

1)Clocking the appliance to ensure the correct firing rate (rate noted on label 33,000 (NG) - High Altitude 32,000 (NG) Btu/h, 31,500 (LP) Btu/h after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fireplace, ensure that the clearances are met.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

Diagram 1

D)Corner

4)This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The L676-1 Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.

6)We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "Exterior Vent Termination Locations"

HEATWAVE

DUCT KIT

The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time.

See HeatWave installation manual for complete details and clearances from side only.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

IMPORTANT NOTE

Combustible material can only be installed to the bottom lip of the fireplace as shown below. The finished floor must not come in contact with the front face of the fireplace. Non-combustible material (see "Framing and Finishing" section) must act as a barrier between the front face and finished floor.

8

Regency® L676-1 Direct Vent Gas Fireplace

Page 8