Regency L676-1 Installation, CONVERSION KIT #522-969FROM NG TO LP, LP Conversion Kit Contains

Models: L676-NG1 L676-1 L676-LP1

1 48
Download 48 pages 15.04 Kb
Page 28
Image 28
CONVERSION KIT #522-969 FROM NG TO LP

INSTALLATION

CONVERSION KIT #522-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

INSTALLATION

LP Conversion Kit Contains:

Qty.

Part #
Description

1

910-582

LP Conversion Coil

1

910-037

LP Pilot Orifi ce

1

904-645

Orifi ce #51

1

904-529

Allen Key

1

918-590

LP Conversion Decal

1

908-528

Red Propane Label

1918-742 Instruction Sheet

1)Remove the right side mesh by gathering the mesh together and lifting the curved end of the rod up and out of the bracket located on the top right of the glass frame.

Now slide the straight end of the rod out from the bracket located on the middle inside top of the outer shell. Repeat for left side.

2)Remove the front cover plate by lifting up off of the pins on the left and right side of the fi rebox.

Front Cover Plate

Right Side Pin Shown

3)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

b.Swing the door out from the top and release the hinge on the left side of the door and lift out.

HingeDoor

c.Place the door on a soft surface to prevent scratching.

4)Remove the burner orifi ce cover plate from the log tray by undoing the 2 screws.

Burner Orifi ce Cover Plate

Latch Location

Latch

5) Remove the grate by undoing the 3 screws.

Right Side Rod with Screen Removed

Grate