LOG SET INSTALLATION

INSTALLATION

LOG SET INSTALLATION

Installation of Brick Panels must be completed before installing the log set.

INSTALLATION

Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.

Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.

Log kit # 522-930 contains the following pieces:

Part #

Description

ALog Rear

BLog Front Left

CLog Front Right

DLog Rear Top Left

ELog Rear Top Center

FLog Cross Right

902-179 Vermiculite

902-153

Rock Wool

946-669Platinum Embers (supplied with packaged manual)

2)Spread vermiculite along the base of the fi rebox.

Vermiculite

3)Place rock wool inbetween the burner tubes and cover the front burner tube by pulling rock wool apart and loosely place as shown. Also place a small amount of rock wool between the log support and the rear of the burner tube. DO NOT block the air inlet or buner ports.

F

B

D

C

E

A4) Separate platinum embers and place over top of the rock wool on the front burner tube. Avoid stacking platinum embers.

The reference numbers (i.e. A) are molded
into the rear of each log.

1)Carefully remove the logs from it's packaging and unwrap them. The logs are fragile, handle with care - do not force into position.