Cornelius 3 service manual Button, Description, Error Type, Displayed, Action, Message

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 23
Image 23
Error Type

 

 

Viper Service Manual

 

 

 

 

 

Table 4

 

 

 

 

Button

Description

 

 

 

 

 

 

 

UNIT

Displays the real time input voltage and frequency being supplied to the

 

 

unit and the low, high or both refrigeration pressures for the unit, depend-

 

 

ing on the settings of the compressor sensors in the Unit Data screen, as

 

 

shown in Figure 31.

 

VER

Displays the version number of the UI, I/O, Motor and Status boards

 

 

installed in the unit

 

 

 

Error Status Menu

The Error Status menu, shown in Figure 11, displays any current errors con- tained in the Error Messages List.

There are three types of errors that can be generated by the system. These error types and a description of their meaning are listed in Table 5.

 

Table 5

 

 

Error Type

Description

 

 

 

 

System

A System error displays the same information across all barrels in the unit.

Barrel

A Barrel error is limited to a specific barrel

 

 

Limp

A Limp error is an error that doesn’t prevent the unit from operating, but limits

 

functionality.

The possible messages from the control system and a description of the errors are shown in Table 6. The button functions are described in Table 7.

 

ERROR

#1 MOTOR PWR

 

STATUS

COMP HIGH

 

12:51P

 

 

MAR 04

 

 

 

 

 

 

 

 

BACK

 

Figure 11. Error Status Screen

 

 

 

 

 

Table 6

 

 

 

 

 

 

 

Displayed

Action

 

Type

Description

 

Message

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT GAS

Off

 

System

Occurs when the barrel outlet temperature exceeds

 

 

 

 

 

115 oF for more than one minute and the compres-

 

 

 

 

 

sor is on.

 

HOT BARREL

Off

 

System

Occurs when the barrel outlet temperature exceeds

 

 

 

 

 

115 oF for more than one minute and the compres-

 

 

 

 

 

sor is off.

 

MTR CTL FAIL

 

 

System

The motor controller reported a fault, triacs are

 

 

 

 

 

shorted and there is a loss of motor on/off function-

 

 

 

 

 

ality.

 

TCO OPEN

 

 

System

TCO (Temperature Cut Off) has occurred on the

 

 

 

 

 

refrigeration oulet of a barrel or the 24VAC power

 

 

 

 

 

has failed.

© 2010, IMI Cornelius Inc.

- 17 -

 

Publication Number: 621360041TBSER

Page 23
Image 23
Cornelius 3 service manual Button, Description, Error Type, Displayed, Action, Message