Cornelius 3 service manual CO2 Setup Menu, Step, Action, Procedure

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 31
Image 31
CO2 Setup Menu

Viper Service Manual

17, allows the user to adjust the viscosity in each barrel to the optimum setting for each type of syrup.

 

VISC

#1 VISC RANGE

6 48-110

 

SETUP

#2 VISC RANGE

6 48-110

 

12:51P

 

 

 

 

MAR 04

 

 

 

 

 

 

 

 

 

BACK

ALL

-

+

Figure 17. Viscosity Setup Screen

Refer to the Installation manual for the recommended settings based on syrup type.

 

 

Table 18

 

 

 

Step

Action

Procedure

 

 

 

 

 

 

1

Set viscosity range

From the Setup screen (Figure 13), open the Viscos-

 

 

ity Setup screen, shown in Figure 17.

2

Select barrel

Use the Up and Down arrows to highlight the desired

 

 

barrel.

3

Select range field

Use Left and Right arrows to select range field

 

 

 

4.

Set range

Use the + or - buttons at the bottom of the display to

 

 

set the desired range.

5

Select barrel

Repeat Steps 2 through 4 for all barrels.

To set all barrels in the system to the same viscosity setting, perform Steps 1 through 4 in Table 18 and then press the ALL button at the bottom of the display while highlighting the viscosity setting you desire for all the barrels. When the viscosity settings are complete, press the BACK button to save the settings and return to the Select menu, shown in Figure 13.

CO2 Setup Menu

The CO2 Setup menu, shown in Figure 18, allows the user to adjust the percentage of time that the CO2 pulse valves are open. This provides an adjustment of the overrun for the unit when using different syrups. The valves use a one second interval dura- tion time. Setting a valve to 45 activates the valve for 450 msec. out of each second.

The CO2 pulse valves may be set between 0 and 100%, in 5% increments. To change the settings of the CO2 pulse valves, perform the procedure in Table 19.

 

CO2

#1 CO2 PULSE %: 45

 

SETUP

#2 CO2 PULSE %

45

 

 

#3 CO2 PULSE %

45

 

12:51P

 

 

 

 

MAR 04

 

 

 

 

 

 

 

 

 

BACK

ALL

-

+

Figure 18. CO2 Pulse Valve Setup Screen

© 2010, IMI Cornelius Inc.

- 25 -

Publication Number: 621360041TBSER

Page 31
Image 31