Cornelius 3 service manual Motor Board Replacement, Action

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 69
Image 69
MOTOR BOARD REPLACEMENT

Viper Service Manual

MOTOR BOARD REPLACEMENT

When replacing or testing electronic components, be sure to wear a static strap that is connected to a chassis ground. This protects the electronic components from any static charge while working on the unit.

The motor board is located in the E-Box, to the right of the control board. It is mounted to the panel on three (3) plastic mounting studs and a threaded stand- off, shown in Figure 55.

 

Table 58

 

 

Step

Action

 

 

 

 

1

Disconnect power from the unit.

2

Connect a static strap to your wrist and any convenient chassis ground on the

 

unit.

3

Unplug the eight (8) connectors from the control board.

 

 

4

Squeeze each of the mounting studs at the corners of the board while care-

 

fully lifting the board.

5

Replace the board with a new board.

 

 

6

Reverse the procedure to install the new board.

 

 

Mounting

Studs

Figure 56. View of Motor Board in E-Box

© 2010, IMI Cornelius Inc.

- 63 -

Publication Number: 621360041TBSER

Page 69
Image 69
Cornelius 3 service manual Motor Board Replacement, Action