Cornelius 3 Motor Run Capacitor Replacement, Action, Step, View of Motor Run Capacitors

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 59
Image 59
MOTOR RUN CAPACITOR REPLACEMENT

Viper Service Manual

Barrel Motor

Mounting

Bolts

Foam

Pack

Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts

 

Table 45

 

 

Step

Action

 

 

 

 

1

Perform the procedure in Steps 1 through 8 of Table 42.

2

Disconnect the motor from the circuit by unplugging the connector.

 

 

3

Remove the motor by removing the four (4) bolts holding the motor to the bar-

 

rel assembly.

4

Install the replacement motor and connect the connector.

 

 

5

Replace the motor seal, scraper blade assembly onto the motor shaft in the

 

barrel, as described in Table 42.

6

Reconnect power to the unit.

 

 

7

Refill the barrel with product. See “Filling a Barrel” on page 29.

 

 

8

When barrel fill is complete, perform a motor calibration. See “Calibrating a

 

Motor” on page 35.

MOTOR RUN CAPACITOR REPLACEMENT

The motor run capacitors, shown in Figure 44, are mounted at the rear of the unit between the barrel motors. To replace a run capacitor, perform the proce- dure in Table 46.

Motor Run

Capacitors

Figure 44. View of Motor Run Capacitors

 

 

Table 46

 

 

 

 

 

 

Step

Action

 

 

 

 

 

 

1

Disconnect power from the unit.

 

© 2010, IMI Cornelius Inc.

- 53 -

Publication Number: 621360041TBSER

Page 59
Image 59
Cornelius 3 service manual Motor Run Capacitor Replacement, Action, Step, View of Motor Run Capacitors