![MOTOR RUN CAPACITOR REPLACEMENT](/images/new-backgrounds/73213/73213117x1.webp)
Viper Service Manual
Barrel Motor
Mounting
Bolts
Foam
Pack
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
| Table 45 |
|
|
Step | Action |
|
|
|
|
1 | Perform the procedure in Steps 1 through 8 of Table 42. |
2 | Disconnect the motor from the circuit by unplugging the connector. |
|
|
3 | Remove the motor by removing the four (4) bolts holding the motor to the bar- |
| rel assembly. |
4 | Install the replacement motor and connect the connector. |
|
|
5 | Replace the motor seal, scraper blade assembly onto the motor shaft in the |
| barrel, as described in Table 42. |
6 | Reconnect power to the unit. |
|
|
7 | Refill the barrel with product. See “Filling a Barrel” on page 29. |
|
|
8 | When barrel fill is complete, perform a motor calibration. See “Calibrating a |
| Motor” on page 35. |
MOTOR RUN CAPACITOR REPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the unit between the barrel motors. To replace a run capacitor, perform the proce- dure in Table 46.
Motor Run
Capacitors
Figure 44. View of Motor Run Capacitors
|
| Table 46 |
|
|
|
|
|
| Step | Action |
|
|
|
|
|
| 1 | Disconnect power from the unit. |
|
© 2010, IMI Cornelius Inc. | - 53 - | Publication Number: 621360041TBSER |