Cornelius 3 service manual Display, Description, Value

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 37
Image 37
Value

 

 

Viper Service Manual

 

 

 

 

 

Table 25

 

 

 

 

Display

Description

 

 

 

 

 

 

 

PRODUCT SOL #1

This selection opens and closes the product solenoids and valves

 

 

for barrel 1

 

CO2 VALVE #1

This selection opens and closes the CO2 solenoic and valve for

 

 

barrel 1

 

LLS VALVE #1

This selection opens and closes the Liquid Line solenoid and

 

 

valve for barrel 1

 

BRL MOTOR #1

This selection turns the barrel 1 motor on and off

 

 

 

To move between one set of barrel parameters to the next, press the Right or Left arrow keys. This moves the highlight to the first entry of the second barrel, etc.

Totals Menu

The Totals menu (Figure 23) shows the cumulative run time of the system, a component of the system or an error. Some individual items may be reset, where available, by highlighting the item and pressing the RESET button. The RESET button is only displayed for items that may be reset, such as hours since the motor seal was changed or the number of compressor cycles. Pressing the BACK button returns to the Choose menu and saves the changes. The descrip- tion of each item in the Totals list is shown in Table 26.

To move between one set of barrel parameters and the next, press the Right or Left arrow keys. This highlights the first entry of the second barrel, etc.

TOTALS

POWER ON

00079:34

 

SLEEP

00034:21

 

SYSTEM ERROR 00003:45

12:51P

COMP RUN

#1 00006:53

COMP CYCLES #1 0000012

MAR 04

BARREL REFG #1 00006:54

 

 

 

 

BACK

 

 

Figure 23. Totals Screen

 

 

 

 

Table 26

 

 

 

 

 

 

 

Display

 

Value

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER ON

 

HHHHH:MM

 

Shows how long the machine has been powered

 

 

 

 

 

up

 

SLEEP

 

HHHHH:MM

 

Shows how long the machine has been in sleep

 

 

 

 

 

mode

 

SYSTEM ERROR

 

HHHHH:MM

 

Shows how long the machine has had a system

 

 

 

 

 

error

 

COMP RUN #1

 

HHHHH:MM

 

Shows how long the compressor has been run-

 

 

 

 

 

ning since the last reset

 

COMP CYCLES #1

 

########

 

Shows the number of compressor cycles since

 

 

 

 

 

the last reset

 

BARREL REFG #1

 

HHHHH:MM

 

Shows how long the barrel has been in refrigera-

 

 

 

 

 

tion mode

 

MOTOR ON #1

 

HHHHH:MM

 

Shows how long the motor has been running on a

 

 

 

 

 

specific barrel

 

MOTOR SEAL #1

 

HHHHH:MM

 

Shows how long it has been since the motor seal

 

 

 

 

 

was inserted on a specific barrel

© 2010, IMI Cornelius Inc.

- 31 -

 

Publication Number: 621360041TBSER

Page 37
Image 37
Cornelius 3 service manual Display, Description, Value