Cornelius 3 service manual Troubleshooting The System, Problem, Probable Cause, Remedy

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 70
Image 70
TROUBLESHOOTING

Viper Service Manual

TROUBLESHOOTING

TROUBLESHOOTING THE SYSTEM

Problem

 

Probable Cause

 

Remedy

 

 

 

 

 

Unit will not run.

A.

Unit not plugged in.

A.

Plug in unit.

 

B.

Circuit breaker.

B.

Reset/replace circuit breaker

 

C.

No power at L1 or L2 on contac-

C.

Check voltage at outlet.

 

 

tor.

 

Check wiring to contactor.

 

D. Low voltage at T1 or T2.

D.

Replace the contactor.

 

 

 

 

 

“Sleep” display on bar-

A.

Sleep time set.

A.

Check sleep programming.

rel status menu.

B.

Clock incorrectly set.

B.

Check sleep programming.

 

C. No wake time set.

C.

Check sleep programming.

Barrel status OFF.

A.

Not activated.

A.

Turn to ON, DFRST or SPIN.

 

B.

Error has shut off motors.

B.

Correct error & turn to ON,

 

 

 

 

DFRST or SPIN.

 

C.

Unit in Diagnostics.

C. Exit diagnostics & turn to ON,

 

 

 

 

DFRST or SPIN.

 

D.

Defective touch switch.

D.

Replace.

 

 

 

 

 

Low/High voltage

A.

Line Voltage out of SPEC (spec is

A.

1 - Check line voltage.

ERROR.

 

205-255 VAC for 60 Hz and 196-

 

2 - Check T1/T2 with Compressor

 

 

265 VAC for 50 Hz).

 

running.

 

B.

Error range 180/260.

B.

Correct line voltage.

 

 

 

 

Frozen Barrel

A.

Low Brix

A. Correct cause and reset Brix.

 

B.

Broken beater bar

B.

Replace beater bar.

 

C.

Broken drive coupler.

C.

Replace the drive coupler.

 

D.

No defrost.

D.

Program defrosts in unit.

 

E. Are defrosts programmed all

E.

Reprogram to all days.

 

 

days?

 

 

Publication Number: 621360041TBSER

- 64 -

© 2010, IMI Cornelius Inc.

Page 70
Image 70