Viper Service Manual
|
| Table 31 |
|
|
|
Step | Action | Procedure |
|
|
|
|
|
|
3 | Select Motor Setup | Use the Up and Down arrows to highlight MOTOR |
|
| SETUP on the Maintenance menu. |
4 | Select the barrel | Use the Up and Down arrows to highlight the desired |
|
| barrel |
5 | Start calibration | Press the CAL button at the bottom of the Motor Setup |
|
| menu to start the calibration process. |
6 |
| The calibration cycle continues for five (5) minutes to allow |
|
| the gearbox to stabalize at temperature and ensure correct |
|
| callibration. At that time the motor stops and it is calibrated. |
7 | Complete the procedure | Press the BACK button at the bottom of the display to |
|
| return to the Maintenance menu. |
|
|
|
System Menu
The System menu is used during production to set up the unit. It also allows the technician to view and change the number of barrels, the number of compres- sors and the number of pressure sensors present in the sytem, as shown in Fig- ure 29. The description of these items is shown in Table 32.
NOTE: Changing these values to a number that doesn’t match the physical number of items in the system generates errors or turns off some of the equipment present in the system.
When the individual fields are highlighted, the display buttons change. Refer to
Table 33 for a listing of the button functions for the various field selections.
| SYSTEM | # OF BARRELS | 2 |
|
| # OF COMPRESSOR 1 | |
|
| SECURITY | OFF |
| 12:51P | CMP #1 SENSORS BOTH | |
| CMP #X SENSORS | LOW | |
| MAR 04 | ||
|
|
| |
|
|
|
|
|
|
|
|
| BACK | - | + |
|
|
|
| Figure 29. System Screen |
| |||
|
|
|
|
| Table 32 |
|
| |
|
|
|
|
|
|
|
|
|
| Display |
|
|
|
| Description |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| # OF BARRELS |
|
| This selection shows the number of barrels in the system and | ||||
|
|
|
| allows the user to change the quantity. |
| |||
| # OF COMPRESSORS |
|
| This selection shows the number of compressors in the sytem. | ||||
|
|
|
| Currently this number is fixed at one and cannot be changed. | ||||
| SECURITY |
|
| This selection allows the user to turn security on or off. | ||||
|
|
|
|
|
|
|
| |
| CMP #X SENSORS |
|
| This selection allows the user to choose which pressure sensors | ||||
|
|
|
| are read for the compressor. |
|
| ||
|
|
|
|
| Table 33 |
|
| |
|
|
|
|
|
|
|
|
|
| Option |
|
| Button 2 |
| Button 3 | Button 4 | Button 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| # of Barrels |
|
|
|
|
| - | + |
| # of Compressors |
|
|
|
|
| - | + |
|
|
|
|
|
|
|
|
|
| Security |
|
|
|
|
| OFF | ON |
|
|
|
|
|
|
|
| |
Publication Number: 621360041TBSER | - 36 - |
|
| © 2010, IMI Cornelius Inc. |