Viper Service Manual
Barrel Maintenance Menu
Purging a Barrel
The Maintenance menu is used for barrel maintenance, diagnostics, BRIX setup and system information. It allows the technician access to the unit during peri- odic maintenance or troubleshooting problems. It sometimes overrides the nor- mal inputs from the system in order to perform this task.
| SELECT | BARREL MAINT | ||
|
| MANUAL DIAG | ||
|
| TOTALS | ||
| 12:51P | BRIX SETUP | ||
| MOTOR SETUP | |||
| MAR 04 | |||
| SYSTEM | |||
|
| |||
|
|
|
|
|
| BACK MAIN SETUP | MAINT | GO |
Figure 20. Select Screen
The Barrel Maintenance menu, shown in Figure 21, allows the service techni- cian to clean, rinse and sanitize the system on a barrel by barrel basis. The bar- rel must be OFF in order to perform the barrel maintenance functions. As a warning to the technician, the “Do Not Drink” status indicators are illuminated on the barrels when entering the Barrel Maintenance menu.
The procedure for purging a barrel is shown in Table 21. The procedure for filling a bar- rel is shown in Table 22. The procedure for running the scraper blade only on a barrel is shown in Table 23 and the procedure for waking up a barrel is shown in Table 25.
BARREL | #1 PURGE |
MAINT | #2 OFF |
12:51P |
|
MAR 04 |
|
|
|
BACK PURGE FILL SPIN
Figure 21. Barrel Maintenance Screen
|
| Table 21 |
|
|
|
Step | Action | Procedure |
|
|
|
|
|
|
1 | Purge a barrel | From the Select menu (Figure 20), open the Barrel |
|
| Maintenance menu, shown in Figure 21. |
2 | Select the barrel | Use the Up and Down arrows to highlight the desired |
|
| barrel |
3 | Select Purge function | Press the PURGE button at the bottom of the display |
|
| to select purge for the highlighted barrel |
Publication Number: 621360041TBSER | - 28 - | © 2010, IMI Cornelius Inc. |