Viper Service Manual
Table 49
Step | Procedure |
8Install the check valve on the new valve and solenoid.
9Remove the valve and solenoid from the mounting bracket and replace it.
10 Reverse the procedure to reinstall the bracket into the unit. 11 Reconnect power to the unit and test the system.
CONDENSER FAN MOTOR REPLACEMENT
The fan motor is located on the top of the unit, as shown in Figure 49. If the motor needs replacement, perform the procedure in Table 50 to remove and reinstall a motor.
Locking | Locking |
Nuts | |
| Nuts |
| Figure 49. Condenser Fan Mounting Nuts |
| Table 50 |
|
|
Step | Action |
|
|
|
|
1 | Disconnect power from the unit. |
2 | Disconnect the fan by unplugging the connector. |
|
|
3 | Remove the four locking nuts securing the fan to the top of the condenser. |
|
|
4 | Lift the fan and shroud off the unit. |
|
|
5 | Remove the four screws and washers securing the fan to the shroud. |
|
|
6 | Replace the fan. |
|
|
7 | Reverse the procedure to install the new fan. |
|
|
8 | Reconnect power to the unit. |
|
|
|
|
COMPRESSOR REPLACEMENT
Caution should be used when working with refrigerants. To replace a compres- sor, perform the procedure in Table 51.
NOTE: Be sure to reclaim refrigerant when replacing compressor.
© 2010, IMI Cornelius Inc. | - 57 - | Publication Number: 621360041TBSER |