Viper Service Manual
PREVENTATIVE MAINTENANCE
SUMMARY
There are no daily maintenance procedures required on the Viper unit other than normal cleanup of spills or overspray and emptying the drip tray. Normal equip- ment maintenance intervals are listed in Table 33. It is recommended that a pre- ventative maintenance procedure be performed every six (6) months. This procedure should include all of the maintenance items described in Table 33 and the following sections.
Table 33
Preventative Maintenance Summary
Maintenance Procedure | Frequency of Maintenance |
|
|
Clean Air Filter | Monthly or more often, as necessary (See |
| Table 34) |
|
|
Check BRIX | Every six months or when changing syrup |
| types (See “BRIX Setup Menu” on page 32.) |
|
|
Seal Change | Every six months |
|
|
Clean Condenser Coil | Every six months or as necessary |
|
|
Sanitize Unit | Every six months or when changing syrup |
| types |
|
|
Check Water Filter | Every six months or if water pressure in the |
| system is low. |
|
|
Change or Rotate Scraper Blades | Every six months |
|
|
Check for Leaks | Every six months |
|
|
Clean BIB Connectors & check opera- | Every six months or when changing syrup |
tion of syrup sold out switches | types. |
|
|
Check Clock Setting | Every six months or when changing to or |
| from daylight savings time |
|
|
Change caged | Every six months or when changing syrup |
Motorman Valves. | types. |
|
|
!CAUTION:
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES.