PREVENTATIVE MAINTENANCE

Viper Service Manual

PREVENTATIVE MAINTENANCE

SUMMARY

There are no daily maintenance procedures required on the Viper unit other than normal cleanup of spills or overspray and emptying the drip tray. Normal equip- ment maintenance intervals are listed in Table 33. It is recommended that a pre- ventative maintenance procedure be performed every six (6) months. This procedure should include all of the maintenance items described in Table 33 and the following sections.

Table 33

Preventative Maintenance Summary

Maintenance Procedure

Frequency of Maintenance

 

 

Clean Air Filter

Monthly or more often, as necessary (See

 

Table 34)

 

 

Check BRIX

Every six months or when changing syrup

 

types (See “BRIX Setup Menu” on page 32.)

 

 

Seal Change

Every six months

 

 

Clean Condenser Coil

Every six months or as necessary

 

 

Sanitize Unit

Every six months or when changing syrup

 

types

 

 

Check Water Filter

Every six months or if water pressure in the

 

system is low.

 

 

Change or Rotate Scraper Blades

Every six months

 

 

Check for Leaks

Every six months

 

 

Clean BIB Connectors & check opera-

Every six months or when changing syrup

tion of syrup sold out switches

types.

 

 

Check Clock Setting

Every six months or when changing to or

 

from daylight savings time

 

 

Change caged o-ring on models w/

Every six months or when changing syrup

Motorman Valves.

types.

 

 

!CAUTION:

Only trained and certified electrical, plumbing and refrigeration technicians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES.