Cornelius 3 service manual Water Pressure Switch Replacement, Step, Action

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 66
Image 66
WATER PRESSURE SWITCH REPLACEMENT

Viper Service Manual

Syrup

Pressure

Switch

 

Figure 52. View of Syrup Pressure Switch and Valve

 

Table 54

 

 

Step

Action

 

 

 

 

1

Disconnect power to the unit

2

Remove the appropriate side panel.

 

 

3

Turn off the syrup supply to the unit.

 

 

4

Drain the syrup from the system.

 

 

5

Disconnect the wires on the pressure switch.

 

 

6

Remove the switch, using two wrenches.

 

 

7

Replace the switch with a new unit.

 

 

8

Reverse the procedure to install the new switch.

 

 

9

Restore the syrup supply and check for leaks.

 

 

10

Check switch operation.

 

 

WATER PRESSURE SWITCH REPLACEMENT

The water pressure switch, shown in Figure 53, is located in back of the water filter, when viewed from the rear of the unit. Access to the switch is obtained by removing the left side panel of the unit, when viewed from the rear. To replace the water pressure switch, perform the procedure in Table 55.

Water

Pressure

Switch

Figure 53. View of Water Pressure Switch

Publication Number: 621360041TBSER

- 60 -

© 2010, IMI Cornelius Inc.

Page 66
Image 66
Cornelius 3 service manual Water Pressure Switch Replacement, Step, Action