Viper Service Manual
CONTROL BOARD REPLACEMENT
When replacing or testing electronic components, be sure to wear a static strap that is connected to a chassis ground. This protects the electronic components from any static charge while working on the unit.
The control board is located in the
Table 57
Step | Action |
1Disconnect power from the unit.
2Connect a static strap to your wrist and any convenient chassis ground on the unit.
3Unplug the eight (8) connectors from the control board.
4Squeeze each of the mounting studs at the corners of the board while care- fully lifting the board.
5Replace the board with a new board.
6Reverse the procedure to install the new board.
Mounting
Studs
Figure 55. View of Control Board in
Software Compatibility
Fruitista sofware is not compatable with standard Viper sofware versions. When ordering replacement/service parts for any unit check the software version of the UI and IO boards and be sure to order the correct board.
Publication Number: 621360041TBSER | - 62 - | © 2010, IMI Cornelius Inc. |