Cornelius 3 service manual Software Compatibility, Control Board Replacement, Step, Action

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 68
Image 68
CONTROL BOARD REPLACEMENT

Viper Service Manual

CONTROL BOARD REPLACEMENT

When replacing or testing electronic components, be sure to wear a static strap that is connected to a chassis ground. This protects the electronic components from any static charge while working on the unit.

The control board is located in the E-Box. It is mounted to the panel on four (4) plastic mounting studs, shown in Figure 55.

Table 57

Step

Action

1Disconnect power from the unit.

2Connect a static strap to your wrist and any convenient chassis ground on the unit.

3Unplug the eight (8) connectors from the control board.

4Squeeze each of the mounting studs at the corners of the board while care- fully lifting the board.

5Replace the board with a new board.

6Reverse the procedure to install the new board.

Mounting

Studs

Figure 55. View of Control Board in E-Box

Software Compatibility

Fruitista sofware is not compatable with standard Viper sofware versions. When ordering replacement/service parts for any unit check the software version of the UI and IO boards and be sure to order the correct board.

Publication Number: 621360041TBSER

- 62 -

© 2010, IMI Cornelius Inc.

Page 68