Cornelius 3 service manual Button, Description, Step, Action, Procedure

Models: 3

1 74
Download 74 pages 15.36 Kb
Page 41
Image 41
Manual background

Viper Service Manual

 

MOTOR

#1 MOTOR TYPE

1

 

SETUP

#2 MOTOR TYPE

2

 

12:51P

 

 

 

 

MAR 04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BACK

CAL

-

+

 

Figure 28. Motor Setup Screen

 

Table 29

 

 

Button

Description

 

 

 

 

BACK

Returns the display to the Select menu

CAL

Verifies the motor settings of a new motor.

-

Decrements the highlighted field

+Increments the highlighted field

 

 

 

Table 30

 

 

 

 

 

Step

Action

Procedure

 

 

 

 

 

 

 

 

1

Set barrel for Motor Type

From the Maintenance menu (Figure 20), open the

 

 

 

Motor Setup menu, shown in Figure 28.

2

Select the barrel

Use the Up and Down arrows to highlight the desired

 

 

 

barrel

3

Select the proper motor

Press the + or - buttons at the bottom of the display to

 

 

type

select the proper motor type

4

Complete the procedure

Press the BACK button at the bottom of the display to

 

 

 

save the settings and return to the Setup menu.

 

 

 

 

Calibrating a Motor

Calibration of motors is typically required when a motor or any associated barrel components (i.e., scraper blades, seal, faceplate, etc.) is removed or replaced. Calibration establishes a new baseline for the motor assembly. This allows the system to determine proper viscosity settings for the new motor. When a new motor is installed in the unit or any of the barrel components are changed or adjusted, the motor should be calibrated by performing the procedure described in Table 31.

!CAUTION:

Calibration must be performed when the product in the barrel is com- pletely liquid. There must not be any ice on the scraper blade.

 

 

 

Table 31

 

 

 

 

 

Step

Action

Procedure

 

 

 

 

 

 

 

 

 

1

Re-assemble barrel

It is VERY IMPROTANT that calibration be performed

 

 

 

when the product in the barrel is in a 100% liquid state.

 

 

 

There can be no ice in the barrel or on the beater bar.

 

2

Defrost the barrel

Select DFRST on the Barrel Status menu (Figure 8). It is

 

 

 

very important that calibration be performed on a fully

 

 

 

defrosted barrel (outlet temperature must be 41°F or barrel

 

 

 

must be purged and refilled with new product). Selecting

 

 

 

DFRST while the barrel is off initiates a full defrost cycle.

© 2010, IMI Cornelius Inc.

- 35 -

Publication Number: 621360041TBSER

Page 41
Image 41
Cornelius 3 service manual Button, Description, Step, Action, Procedure