Viper Service Manual
|
| Table 16 |
|
|
|
Step | Action | Procedure |
|
|
|
|
|
|
9 | Select WAKEUP | Use the up and down arrows to highlight |
|
| WAKEUP and repeat Steps 5 through 7 to set the |
|
| WAKEUP times. |
When the sleep and wakeup settings are complete, press the BACK button to save the settings and return to the Select menu, shown in Figure 13.
Setting Defrost Lockout
From the Barrel Status menu, shown in Figure 8, press the MENU button and then press the SETUP button to display the Setup menu. Use the up and down arrows on the right of the control to highlight the Events Setup menu, then press GO to enter the menu (Figure 16).
The lockout can also be set day by day or for all days with up to three lockout periods of four hours each per day. These lockout periods may be overlapped to provide from four to 12 hours of defrost lockout, if desired. When the periods are overlapped, it is recommended that the defrost lockouts for sequential lockout periods be overlapped by 15 minutes. The defrost lockout affects all barrels in the unit. To set the defrost lockouts, perform the procedure in Table 17.
|
| Table 17 |
|
|
|
Step | Action | Procedure |
|
|
|
|
|
|
1 | Set defrost lockout | Open Events Setup menu, shown in Figure 16 |
2 | Select DAY | The DAY field is highlighted. |
|
|
|
3 | Set DAY | Use the + and - buttons at the bottom of the display |
|
| to set the desired day or all days. |
4 | Select DEFROST LOCK | Use the up and down arrows to highlight |
| 1 | DEFROST LOCK 1. |
5 | Set hour field | Use left and right arrows to select hour field |
6 |
| Use the + and - buttons at the bottom of the display |
|
| to set the desired hour. |
7 | Set minute field | Use left and right arrows to select minute field |
|
|
|
8 |
| Use the + and - buttons at the bottom of the display |
|
| to set the desired minute (in 15 min. increments). |
9 | Select AM/PM field | If the 12 hour clock option is selected, use the left |
|
| and right arrows to select the AM/PM field. |
10 |
| Use the + button at the bottom of the display to set |
|
| the AM/PM field. |
11 | Select DEFROST LOCK | Repeat Steps 2 through 10 for the DEFROST |
| 2 | LOCK 2 time, if desired. |
12 | Select DEFROST LOCK | Repeat Steps 2 through 10 for the DEFROST |
| 3 | LOCK 3 time, if desired. |
When the defrost lockout settings are complete, press the BACK button to save the settings and return to the Select menu, shown in Figure 13.
Viscosity Setup Menu
The viscosity maintained in the freeze barrels depends on the type of product being served. Some products are served best at a higher viscosity, while others require a lower viscosity for best quality. The Viscosity menu, shown in Figure
Publication Number: 621360041TBSER | - 24 - | © 2010, IMI Cornelius Inc. |