Regency L676-NG1, L676-1 Installation, Venting Arrangements, FPI Kit #, Length, Contains, Notes

Models: L676-NG1 L676-1 L676-LP1

1 48
Download 48 pages 15.04 Kb
Page 15
Image 15
VENTING ARRANGEMENTS

INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency® Direct Vent System

These venting systems, in combination with the L676-1, have been tested and listed as a direct vent system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the L676-1 using a flexible vent.

FPI Kit #

Length
Contains:

#946-615

4 Feet

1)

8” flexible liner (Kit length)

 

 

2)

5” flexible liner (Kit length)

 

 

3)

spring spacers

#946-618

6 Feet

4)

thimble

 

 

5)

AstroCap termination cap

 

 

6)

screws

 

 

7)

tube of Mill Pac

#946-616

10 Feet

 

 

8)

plated screws

 

 

9)

S.S. screws #8 x 1-1/2” drill point

 

 

10)

vinyl siding standoff

 

 

 

 

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from FPI may be used for Flex installations.

3) Horizontal vent must be supported every 3 feet.

4) Awall thimble is mandatory for all horizontal terminations due to high temperatures.

INSTALLATION

Regency® L676-1 Direct Vent Gas Fireplace

15

Page 15
Image 15