REGENCY® DIRECT VENT FLEX SYSTEM

INSTALLATION

REGENCY® DIRECT VENT FLEX SYSTEM

Horizontal Terminations Only

This venting system, in combination with the P33-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .

Regency® Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33-4 with a maximum run of 2

feet. If installing the P33 with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 (10 ft) or see "Rigid Pipe Venting Systems" Section for alternate venting arrangements.

1)6-7/8" dia. fl exible liner (2 ft. length)

2)4" dia. fl exible liner (2 ft. length)

3)spring spacers (3)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1-1/2" drill point, stainless steel (4)

Notes:

Wall Thimble (2 pc)

(required in

Canada only)

 

AstroCapTM

4" (102mm)

Termination Cap

dia. flue pipe

(Part# 946-523/P)

spring spacer

1)

Liner sections should be continuous

 

without any joints or seams.

2)

Only Flex pipe purchased from Regency®

6-7/8"

See Figure 1 below for Alternate Caps.

may be used for Flex installations.

(173mm) dia. Flue pipe

IMPORTANT

If using any Cabinet Mantels with Part # 510956, 510958, 510962, 510964 and 510834 the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position.

Also Rigid Vent venting cannot be used with any of the mantels noted above. See Price Pages for alternative options.

MINIMUM

RIGID PIPE CENTER-LINE

MINIMUM

FLEX KIT CENTER-LINE

Alternate

Horizontal

Termination

Caps

Figure 1

 

Wherever necessary due to

 

external location of cap, the

 

AstroCapcanbereplacedwith

 

the FPI Riser Vent Termination

 

Cap or the Dura-Vent Snorkel

 

Termination Cap.