Regency P33-NG4 installation manual Installation, Horizontal Venting with Two 2 90o Elbows

Models: P33-NG4

1 52
Download 52 pages 58.5 Kb
Page 19
Image 19
INSTALLATION

 

INSTALLATION

 

 

 

 

Horizontal Venting with Two (2) 90o Elbows

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these options, maximum

 

 

 

 

total pipe length is 30 feet

A)

1'

Min.

3' Max.

with minimum of 6 feet total

B)

2'

Min.

4' Max.

vertical and maximum 8 feet

 

 

 

 

total horizontal.

C)

3'

Min.

5' Max.

 

D)

4'

Min.

6' Max.

Please note minimum 1

 

 

 

 

foot between 90o elbows is

E)

5'

Min.

7' Max.

required.

F)

6'

Min.

8' Max.

 

Option

H

 

V

H+H1+H2

With these

options,

 

 

 

 

 

maximum total pipe

A)

1' Max.

1'

Min.

3' Max.

length is 30 feet with

 

 

 

 

 

minimum of 11 feet

B)

2' Max.

3'

Min.

5' Max.

total vertical and

C)

3' Max.

5'

Min.

6' Max.

maximum 9 feet total

horizontal.

 

D)

4' Max.

7'

Min.

7' Max.

P l e a s e

n o t e

E)

5' Max.

9'

Min.

8' Max.

minimum

1 foot

 

 

 

 

 

between90o elbows

F)

6' Max.

11' Min.

9' Max.

is required.

Horizontal Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H

 

V

H+H1

With these options,

 

 

 

 

 

maximum total pipe

A)

1' Max.

1'

Min.

3' Max.

length is 30 feet with

 

 

 

 

 

minimum of 8 feet total

B)

2' Max.

2'

Min.

5' Max.

vertical and maximum 8

C)

3' Max.

4'

Min.

6' Max.

feet total horizontal.

 

D)

4' Max.

6'

Min.

7' Max.

Please note minimum

 

 

 

 

 

1 foot between 90o

E)

5' Max.

8'

Min.

8' Max.

elbows is required.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P33-NG4 Installation, Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows