![INSTALLATION](/images/new-backgrounds/54639/5463937x1.webp)
| INSTALLATION |
|
|
|
|
Horizontal Venting with Two (2) 90o Elbows | Horizontal Venting with Three (3) 90o Elbows |
One 90o elbow = Two 45o elbows. | One 90o elbow = Two 45o elbows. |
Option |
| V | H + H1 | With these options, maximum | |
|
|
|
| total pipe length is 30 feet | |
A) | 1' | Min. | 3' Max. | ||
with minimum of 6 feet total | |||||
B) | 2' | Min. | 4' Max. | vertical and maximum 8 feet | |
|
|
|
| total horizontal. | |
C) | 3' | Min. | 5' Max. | ||
| |||||
D) | 4' | Min. | 6' Max. | Please note minimum 1 | |
|
|
|
| foot between 90o elbows is | |
E) | 5' | Min. | 7' Max. | ||
required. | |||||
F) | 6' | Min. | 8' Max. |
|
Option | H |
| V | H+H1+H2 | With these | options, | |
|
|
|
|
| maximum total pipe | ||
A) | 1' Max. | 1' | Min. | 3' Max. | |||
length is 30 feet with | |||||||
|
|
|
|
| minimum of 11 feet | ||
B) | 2' Max. | 3' | Min. | 5' Max. | |||
total vertical and | |||||||
C) | 3' Max. | 5' | Min. | 6' Max. | maximum 9 feet total | ||
horizontal. |
| ||||||
D) | 4' Max. | 7' | Min. | 7' Max. | P l e a s e | n o t e | |
E) | 5' Max. | 9' | Min. | 8' Max. | minimum | 1 foot | |
|
|
|
|
| between90o elbows | ||
F) | 6' Max. | 11' Min. | 9' Max. | ||||
is required. |
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option | H |
| V | H+H1 | With these options, | |
|
|
|
|
| maximum total pipe | |
A) | 1' Max. | 1' | Min. | 3' Max. | ||
length is 30 feet with | ||||||
|
|
|
|
| minimum of 8 feet total | |
B) | 2' Max. | 2' | Min. | 5' Max. | ||
vertical and maximum 8 | ||||||
C) | 3' Max. | 4' | Min. | 6' Max. | feet total horizontal. | |
| ||||||
D) | 4' Max. | 6' | Min. | 7' Max. | Please note minimum | |
|
|
|
|
| 1 foot between 90o | |
E) | 5' Max. | 8' | Min. | 8' Max. | elbows is required. |
Regency® | 19 |