Regency P33-NG4 Do not overtighten the screw. Recommended to grip, the wrench by the short side

Models: P33-NG4

1 52
Download 52 pages 58.5 Kb
Page 28
Image 28
Fig. 1

INSTALLATION

7)

Turn control knob to the “OFF” position.

12) Using the Allen wrench as shown in

 

 

Fig.4, rotate the screw clockwise until

8)

Remove the black protection cap by

snug, do not overtighten.

 

hand from the high-low knob (Fig.1).

 

 

 

 

 

 

 

15)

Reverse step 2.

16)

Attach the label "This unit has been

 

converted to LPG" near or on top of the

 

serial # decal.

17)

Replace yellow "NG" label with red

 

"LPG" label.

18)

Check for gas leaks.

19)

Check inlet and outlet pressures.

20)

Check operation of fl ame control.

Fig. 1

9)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to grip

the wrench by the short side.

13)Verify that if the conversion is from NG to LPG, the screw must be re- assembled with the red o-ring visible (Fig. 5).

21) Check for proper fl ame appearance and

glow on logs.

Red o-ring visible

Fig.5

LPG Configuration

Fig.2

10)Check that the screw is clean and if necessary remove dirt.

11)Flip the screw (Fig. 3).

Fig.3

14)Re-assemble the black protection cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

28