Ignitor

INSTALLATION

Installation of the DC Sparker for the P33-4 Unit Only:

1)Locate the Piezo Ignitor situated at the side of valve.

2)Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket.

Ignitor

Wire

Piezo

Ignitor

3)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the DC Sparker.

DC

Sparker

Ignitor

Wire

4)Install the 3/4" nylon plug to cover up the hole on the mounting bracket.

5)Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit.

Piezo

Ignitor

6)Locate the ground lug at the receptical box, left of the unit.

7)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

8)Install the 1/2" bushing to the heat shield.

9)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

10)Plug the DC spark generator wires to the DC Sparker.

11)Connect the ground wire to the DC Sparker mounting bracket.

12)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

Battery

Compartment

13)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

14)Find a location which is not too hot and is easy to reach for changing the battery.

Note: It should be kept away from the chain.

Chain

15)Tie up the loose wire with the wire clip.