EXTERIOR VENT TERMINATION LOCATIONS

INSTALLATION

EXTERIOR VENT TERMINATION LOCATIONS

G

A

VentHeight

Meters

0.61

0.61

0.61

0.76

0.99

1.22

1.52

1.83

2.13

2.29

2.44

Minimum

Feet

2

2

2

2.5

3.25

4

5

6

7

7.5

8

 

RoofPitch

flatto7/12

over7/12to8/12

over8/12to9/12

over9/12to10/12

over10/12to11/12

over11/12to12/12

over12/12to14/12

over14/12to16/12

over16/12to18/12

over18/12to20/12

over20/12to21/12

 

B-VentOnly:Ifventislessthan10ft.

wallfrom(3m)-locateraincapnotless (600mm)ft.2thanabovewall.

 

(600mm)

 

 

 

DoNever thisdothis

 

 

 

 

 

.ft 2

 

 

 

 

 

 

 

18”

24”

 

A

 

 

 

L

 

 

 

N

 

 

 

J

 

 

Closed

H

Openable

 

Fixed

 

 

 

 

B

 

 

 

E

K A

 

 

 

A

 

 

D

Openable

 

 

Closed

B C

A

 

Fixed

F

 

 

 

M

 

24”

B

 

 

Area where terminal is not permitted

Supply Outlet

AirA

TerminationVent

Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally

from the centerline of the regulator.

Clearance to service regulator vent outlet *(min. 36"/90cm)

Clearance to non-mechanical air supply inlet to building or the combustion air inlet to

any other appliance *(12"/30cm) #(9"/23cm)

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

#3' (91cm) above if within 10' (3m) horizontally.

Clearance above paved sidewalk or a paved driveway located on public property

*(min. 84"/2.1m)

Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

H=

 

J=

K=

 

L=

 

M=

 

N=

Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

Clearance to permanently closed window *(min. 12"/30cm)

Vertical clearance to ventilated soffit located above the terminal within a horizontal

distance of (24"/60cm) from the centerline of the terminal (min. 18"/46cm) check with

local code.

Clearance to unventilated soffit (min. 15"/38cm)

Clearance to outside corner: with AstroCap Termination Cap (min. 6"/15cm), with

Dura-Vent Termination Cap (12"/30cm)

Clearance to inside corner: with AstroCap Termination Cap (min. 6"/15cm), with Dura- Vent Termination Cap (12"/30cm)

A=

B=

C=

D=

 

 

E=

F=

 

G=

Note: - A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. - Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. - If the vent termination is accessible, a certified guard shall be installed. * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances. # In accordance with the current ANSI Z223.1/NFPA 54, Natioinal Fuel Gas Code.

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

11