INSTALLATION
RIGID PIPE VENTING ARRANGEMENTS
Horizontal Terminations
REGENCY® DIRECT VENT SYSTEM (FLEX)
(Propane & Natural Gas)
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one 90o elbow).
Note: Must use optional rigid pipe adaptor (Part #
A vent guard should be used whenever the terminationislowerthanthespecifiedminimum or as per local codes.
Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.
• Maintain clearances to combustibles.
•Horizontal vent must be supported every 3 feet.
• Firestops are required at each floor level and whenever passing through a wall.
Minimum | Minimum |
Simpson | Flex Kit |
| IMPORTANT |
| If using any Cabinet Mantels with Part # |
| 510956, 510958, 510962, 510964 and |
| 510834 the wall thimble must be secured fi rst |
| and venting must be attached to unit before |
| sliding into fi nal position. |
| Also Rigid Vent venting cannot be used with |
| any of the mantels noted above. See Price |
| Pages for alternative options. |