REGENCY® DIRECT VENT SYSTEM (FLEX)

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS

Horizontal Terminations

REGENCY® DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45o and one 90o elbow (two 45o elbows equal one 90o elbow).

Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section)

A vent guard should be used whenever the terminationislowerthanthespecifiedminimum or as per local codes.

Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.

• Maintain clearances to combustibles.

Horizontal vent must be supported every 3 feet.

• Firestops are required at each floor level and whenever passing through a wall.

Minimum

Minimum

Simpson Dura-Vent Center-Line

Flex Kit Center-Line

 

IMPORTANT

 

If using any Cabinet Mantels with Part #

 

510956, 510958, 510962, 510964 and

 

510834 the wall thimble must be secured fi rst

 

and venting must be attached to unit before

 

sliding into fi nal position.

 

Also Rigid Vent venting cannot be used with

 

any of the mantels noted above. See Price

 

Pages for alternative options.