Regency P33-NG4 installation manual Vertical Venting with Three 3 90o Elbows, Option, H + H1

Models: P33-NG4

1 52
Download 52 pages 58.5 Kb
Page 21
Image 21
Vertical Venting with Three (3) 90o Elbows

INSTALLATION

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H

V

H + H1

V + V1

With these options, max. total

A)

1' Max.

1' Min.

3' Max.

3' Min.

pipe length is 30 feet with min.

B)

2' Max.

2' Min.

4' Max.

5' Min.

of 11 feet total vertical and

 

 

 

 

 

max. 7 feet total horizontal.

C)

3' Max.

3' Min.'

5' Max.

7' Min.

 

 

 

 

 

Please note omin. 1 foot

D)

4' Max.

4' Min.

6' Max.

9' Min.

 

 

 

 

 

between 90 elbows is

E)

5' Max.

5' Min.

7' Max.

11' Min.

required.

 

 

 

 

 

 

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

H + H1

V + V1

With these options, max.

A)

2' Min.

3' Max.

4' Min.

total pipe length is 30 feet

 

 

 

 

with min. of 10 feet total

B)

3' Min.

4' Max.

6' Min.

C)

4' Min.

5' Max.

7' Min.

vertical and max. 8 feet total

 

 

 

 

horizontal.

 

D)

5' Min.

6' Max.

8' Min.

 

Please note

min. 1 foot

E)

6' Min.

7' Max.

9' Min.

between 90o

elbows is

 

 

 

 

required.

 

F)

7' Min.

8' Max.

10' Min.

 

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace

21

Page 21
Image 21
Regency P33-NG4 installation manual Vertical Venting with Three 3 90o Elbows, Option, H + H1